15–25%
of construction cost is the facade alone — the building's largest single surface, and its primary interface with the climate.1
Solapane builds electricity generation, energy storage, ventilation, heating and cooling into the curtain wall itself. In hourly simulation of a 30-storey Toronto tower, the perimeter zones behind the facade needed 59% less purchased energy than the same zones behind a conventional curtain wall — with the facade supplying nine-tenths of what heating, cooling and ventilation consume.
The drawing steps through the three PV coverage options. The figures below are for the modelled standard configuration, 370 W of PV per bay, and do not change with it.
PV can be specified in the spandrel alone, in the spandrel and the mechanical fascia, or in all three zones including transparent vision glazing. The mechanical cassette at the floor holds the heat pump, battery and ventilation in every configuration — drawing outside air, rejecting heat outside, and supplying conditioned air to the room through the sill.
A conventional glass tower lets heat in and out, then spends decades of operating budget countering it with mechanical equipment. Together, the facade and the systems that compensate for it account for roughly a third of construction cost.1
of construction cost is the facade alone — the building's largest single surface, and its primary interface with the climate.1
is mechanical, electrical and plumbing — much of it sized to correct for what the facade lets through.1
of an office building’s annual operating expense is energy — the largest controllable cost, every year the building stands.2
a year to heat, cool and ventilate just the perimeter zones of a 30-storey tower behind a conventional curtain wall — from the simulation below.3
Solapane treats the facade not as a problem to mitigate, but as part of the solution.
We modelled a 30-storey, 25,000 sq ft-per-floor reference tower in EnergyPlus — full 8,760-hour annual runs against a Toronto weather file — comparing Solapane against a conventional double-glazed curtain wall with gas-fired perimeter heating. The accounting covers the perimeter zones — the 4.6 m-deep strip behind the facade on every floor — and includes their lighting and plug loads on both sides, so the percentage is what those zones draw from the meter.
| Annual, perimeter zones (MWh) | Basis | Conventional baseline | Solapane |
|---|---|---|---|
| Heating | Gas boiler / cassette heat pump with resistance backup | 914 gas | 162 |
| Cooling | DX, COP 3.0 in both cases | 723 | 599 |
| Fans | Supply fans, occupied-continuous / cycling | 787 | 504 |
| Interior lighting | 8 W/m², office schedule | 622 | 622 |
| Plug loads | 7.5 W/m², office schedule | 809 | 809 |
| Facade PV generated | Gross annual output, 370 W per bay | — | 1,212 |
| Of which used on site | Met load hour by hour, through the cassette batteries; surplus not credited | — | −1,121 |
| Purchased energy | 3,855 | 1,575 (−59%) |
Three effects compound. The envelope cuts the load: heating energy falls 82% and fan energy 36%. Heat-pump conditioning meets that load without gas. And facade generation with on-cassette storage supplies 1,121 MWh on site — 89% of what heating, cooling and ventilation consume. Lighting and plug loads are untouched; they are the floor a building cannot go below without changing how it is used.
The model excludes any improvement in heat-pump efficiency from the facade cavity. Tropical-climate runs against a Bangkok weather file are complete; results are available under NDA.
These are simulation results produced in-house. Independent third-party testing of a full working facade unit is the next milestone, and no performance claim should be treated as validated until that testing is complete.
For decades the facade has been a barrier, and the building has spent energy compensating for its limits. Solapane reverses that relationship: the envelope becomes an active contributor to energy performance, comfort and resilience.
Cuts what a commercial building spends keeping occupants comfortable, moving the envelope toward net-zero performance rather than merely slowing losses.
A warmer, more stable interior surface and better air at the perimeter — where cold downdraft and glare are the daily complaints, and where people actually sit.
Engineered in Canada for northern winters, where conventional building systems lose both efficiency and comfort exactly when they are needed most.
Built on decades of unitized curtain-wall manufacturing — for new towers, and for the large stock of aging commercial facades due for replacement.
Buildings face the climate differently in Toronto than in Singapore. Solapane meets that with two configurations of the same active-facade platform, so the system fits the market rather than the other way around.
Full heating and cooling across the year, for markets where buildings must do both. The flagship configuration, engineered for northern winters and four-season climates alike.
Canada · United States · Europe · East Asia
A cooling-focused configuration for hot and tropical regions, where managing solar load is the year-round challenge and heating capacity would sit idle.
Middle East · South Asia · Southeast Asia · Australia
Engineered first for Canadian winters, where building systems are pushed hardest. A system that performs there is built to perform anywhere.
Most Canadian commercial buildings predate modern envelope standards. Solapane is designed for retrofit, not only for new construction.
Cuts carbon at the building itself, supporting net-zero targets without waiting on grid expansion or new generation capacity.
U.S. provisional application filed July 2026, with PCT filing to follow. Owned by RZG Technologies, developed in British Columbia.
Solapane is in active development and pre-revenue, with foundational intellectual property filed. The path is deliberate: prove the system and earn independent validation before any broad commercial push.
Design concept complete, hourly energy simulation done. Provisional patent filed July 2026; PCT to follow within twelve months. First reference-building candidates identified in Vancouver.
Build a full working facade unit and confirm its performance through independent, third-party testing rather than in-house modelling alone.
A live building, with a full annual cycle of real-world performance data standing as the commercial reference.
Explore a first reference installation — performance objectives, facade scope and partnership terms.
Discuss a pilotREITs, pension funds and clean-tech investors. Register interest and receive materials under NDA.
Register interestNRC IRAP, NRCan and BC program reviewers — scoping, eligibility and alignment.
ConnectFacade, glazing and building-systems manufacturers interested in co-development under NDA.
Explore partnershipA British Columbia clean-technology company developing advanced facade and envelope systems.
Solapane is led by Robert Grandbois, a mechanical engineer with more than 45 years across HVAC and high-performance curtain-wall systems. In 1985 he and two partners licensed the Visionwall high-performance envelope system; their company delivered its first projects in 1987 and opened its Edmonton manufacturing plant in 1989 — a four-decade record of taking advanced facade technology from licence through to production.
That history is the reason Solapane starts from manufacturability rather than from a laboratory prototype. The system is designed around unitized curtain-wall production methods that already exist at scale.
We're engaging building owners, institutional partners and government programs, and sharing full technical detail with qualified parties under NDA.
No securities offering is currently being made. Interested parties are invited to register interest under NDA; detailed materials follow upon qualification.